I have found some problems when using nested routes with the plugin: lighthouse cannot resolve start_url when in nested path route, for example just request https://vitesse.netlify.app/hi/a in private mode on chrome, open dev tools and run lighthouse with PWA check checked:

imagen

The problem in question can be solved just adding the scope to the manifest.webmanifest file and also initializing it with the basePath.

By default it is initialized as ./, and I don’t know if this value is ok to be used as scope when registering the service worker. I register it using router.isReady callback instead on index page and change the default pattern to be /, and so the header, the manifest.webmanifest and the registration matches:

imagen

This is because it seems that the nested parent path acts as a new scope, that is distinct from the missing scope.

Another think that I don’t know if it is required is to add a header like that to the html (I just add it as a http header from the server side):

service-worker-allowed: `${basePath}`

Here is a working manifest.webmanifest.

You can see a working sample here: https://cancer.malvarez.info/conozca-su-riesgo, then click on + icon and run the test (it is with vite 1 + vitesse 1, I’m migrating it to vite 2 + vitesse 2).

About this issue

  • Original URL
  • State: closed
  • Created 3 years ago
  • Comments: 27 (25 by maintainers)

Most upvoted comments

Something is wrong @antfu , go to vitesse demo page, then open manifest from devtools, it is base64 encoded.

You must configure netlify to server manifest.webmanifest files with application/manifest+json content type, it is being served with application/octet-stream content type.

imagen

The scope would be set to base by default from v0.4.6. I think it’s good to make things just works if possible, thanks for the notice and suggestions