DHTNew: Problem: wrong values at negative temperatures an ESP8266 and DHT22

I use the DHT22 in combination with an ESP8266 and this lib. When having negative temperatures, the resulting value of getTemperature() is -3278.6 at -0.1°C To fix negatives values a recalculation is nessecary:

#include <stdint.h>
if(temperature < 0)
 {
   temperature = (temperature = (INT16_MAX - temperature*-10)*-0.1; - temperature*-10)*-0.1;
 }

This was tested with Arduino IDE against lib version 0.4.3, installed via Arduino library manager.

About this issue

  • Original URL
  • State: closed
  • Created 6 years ago
  • Comments: 16 (15 by maintainers)

Most upvoted comments

I use the DHT22 in combination with an ESP8266 and this lib. When having negative temperatures, the resulting value of getTemperature() is -3278.6 at -0.1°C To fix negatives values a recalculation is nessecary:

#include <stdint.h>
if(temperature < 0)
 {
   temperature = (temperature = (INT16_MAX - temperature*-10)*-0.1; - temperature*-10)*-0.1;
 }

This was tested with Arduino IDE against lib version 0.4.3, installed via Arduino library manager.

This is a magic of C++, real transform equivalent:

temperature = -temperature - 3276.7

It because AM2301 has inside not DHT22(1) but AHT10.