homebridge-switchbot: BUG: [SwitchBot] Internal Server Error, An unexpected error on the SmartThings servers has occurred. These errors should be rare, statusCode: 500

Describe the Bug

When attempting to interact with WoIOSensor (Kitchen Sensor) and Smart Lock (LightBolt) devices using the homebridge-switchbot plugin, I receive an “Internal Server Error” with a status code of 500. Additionally, an “Unknown statusCode: undefined” error is logged. This suggests an unexpected error on the SmartThings servers.

To Reproduce

  1. Install and configure the homebridge-switchbot plugin.
  2. Add WoIOSensor (Kitchen Sensor) and Smart Lock (LightBolt) devices to the configuration.
  3. Observe the error logs when Homebridge attempts to interact with these devices.

Expected Behavior

The plugin should successfully interact with the WoIOSensor and Smart Lock devices without encountering server errors.

Relevant Log Output

[4/7/2024, 12:10:02 AM] [SwitchBot] WoIOSensor: Kitchen Sensor Internal Server Error,   An unexpected error on the SmartThings servers has occurred. These errors should be rare, statusCode: 500
[4/7/2024, 12:10:02 AM] [SwitchBot] WoIOSensor: Kitchen Sensor Unknown statusCode: undefined, Submit Bugs Here: ' + 'https://tinyurl.com/SwitchBotBug
[4/7/2024, 12:10:13 AM] [SwitchBot] Smart Lock: LightBolt Internal Server Error,        An unexpected error on the SmartThings servers has occurred. These errors should be rare, statusCode: 500
[4/7/2024, 12:10:13 AM] [SwitchBot] Smart Lock: LightBolt Unknown statusCode: undefined, Submit Bugs Here: ' + 'https://tinyurl.com/SwitchBotBug
[4/7/2024, 12:25:15 AM] [SwitchBot] Internal Server Error,      An unexpected error on the SmartThings servers has occurred. These errors should be rare, statusCode: 500
[4/7/2024, 12:25:15 AM] [SwitchBot] Unknown statusCode, statusCode: undefined, Submit Bugs Here: ' + 'https://tinyurl.com/SwitchBotBug

Config for homebridge-switchbot

{
    "name": "SwitchBot",
    "credentials": {
        "token": "REDACTED",
        "secret": "REDACTED",
        "notice": "Keep your Token & Secret a secret!"
    },
    "options": {
        "devices": [
            {
                "deviceId": "REDACTED",
                "configDeviceName": "Kitchen Sensor",
                "hide_device": false,
                "configDeviceType": "WoIOSensor",
                "connectionType": "OpenAPI",
                "webhook": true,
                "lock": {
                    "activate_latchbutton": false
                },
                "history": true,
                "firmware": "0.4",
                "external": true
            },
            {
                "deviceId": "REDACTED",
                "configDeviceName": "LightBolt",
                "hide_device": false,
                "configDeviceType": "Smart Lock",
                "connectionType": "OpenAPI",
                "webhook": true,
                "lock": {
                    "activate_latchbutton": false
                },
                "firmware": "2.1.1",
                "refreshRate": 20,
                "external": false,
                "logging": "standard"
            },
            {
                "deviceId": "REDACTED",
                "configDeviceName": "LightHub 2",
                "hide_device": true,
                "lock": {
                    "activate_latchbutton": false
                }
            }
        ],
        "refreshRate": 60
    },
    "_bridge": {
        "username": "REDACTED,"
        "port": REDACTED
    },
    "platform": "SwitchBot"
}

Screenshots

No response

Device and Model

Outdoor Thermohygrometer, SmartLock

Node.js Version

v20.12.1

NPM Version

v10.5.0

Homebridge Version

v1.7.0

Homebridge Switchbot Plugin Version

v3.4.0

Homebridge Config UI X Plugin Version

v4.56.1

Operating System

macOS

About this issue

  • Original URL
  • State: closed
  • Created 3 years ago
  • Comments: 39 (2 by maintainers)

Commits related to this issue

Most upvoted comments

Thanks @sametguzeldev, I have added this to the latest beta. maxRetries and delayBetweenRetries are both customizable in the config.

I had the same issue, using an Smart Lock and Hub 2:

Node.js Version: v20.12.1 Homebridge Version: v1.8.1 Homebridge Switchbot Plugin Version: v3.4.0 Smart Lock Firmware Version: V6.6

BUT it got fixed yesterday night after an update of the Smart Lock firmware to version V6.8.

I’ve been getting these unknown statuscode errors constantly across all my devices (meters, curtains, etc.) on v3.4.0. (had opened a separate issue a while ago). The latest beta V3.5.0-beta22 seems to have fixed it.

Thanks!

Sorry nothing I can do about this. This is all the SwitchBot API. SwitchBot will have to resolve this.

And no I don’t work for switchBot, I just manage this plugin.