openhab-addons: [MQTT] Cannot send STOP to generic roller shutter
Since I upgraded from 4.0.4 to 4.1.1, I can’t send STOP command to my mqtt channel configured as roller shutter. UP and DOWN still work
Expected Behavior
Send a message “STOP” to the topic linked to a generic roller shutter MQTT channel when the related item got the STOP command
Current Behavior
sendCommand(STOP) to the item responds OK but no message in the mqtt topic.
In the logs, I got this exception :
[ERROR] [nal.common.AbstractInvocationHandler] - An error occurred while calling method 'ThingHandler.handleCommand()' on 'org.openhab.binding.mqtt.generic.internal.handler.GenericMQTTThingHandler@8ec84e': STOP is not a valid command for MQTT.
java.lang.IllegalArgumentException: STOP is not a valid command for MQTT.
at org.openhab.binding.mqtt.generic.values.RollershutterValue.parseType(RollershutterValue.java:97) ~[?:?]
at org.openhab.binding.mqtt.generic.values.RollershutterValue.parseCommand(RollershutterValue.java:137) ~[?:?]
at org.openhab.binding.mqtt.generic.ChannelState.publishValue(ChannelState.java:369) ~[?:?]
at org.openhab.binding.mqtt.generic.AbstractMQTTThingHandler.handleCommand(AbstractMQTTThingHandler.java:153) ~[?:?]
at jdk.internal.reflect.NativeMethodAccessorImpl.invoke0(Native Method) ~[?:?]
at jdk.internal.reflect.NativeMethodAccessorImpl.invoke(NativeMethodAccessorImpl.java:77) ~[?:?]
at jdk.internal.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethodAccessorImpl.java:43) ~[?:?]
at java.lang.reflect.Method.invoke(Method.java:568) ~[?:?]
at org.openhab.core.internal.common.AbstractInvocationHandler.invokeDirect(AbstractInvocationHandler.java:147) [bundleFile:?]
at org.openhab.core.internal.common.InvocationHandlerSync.invoke(InvocationHandlerSync.java:59) [bundleFile:?]
at jdk.proxy479.$Proxy594.handleCommand(Unknown Source) [?:?]
at org.openhab.core.thing.internal.profiles.ProfileCallbackImpl.handleCommand(ProfileCallbackImpl.java:95) [bundleFile:?]
at org.openhab.core.thing.internal.profiles.SystemDefaultProfile.onCommandFromItem(SystemDefaultProfile.java:49) [bundleFile:?]
at jdk.internal.reflect.NativeMethodAccessorImpl.invoke0(Native Method) ~[?:?]
at jdk.internal.reflect.NativeMethodAccessorImpl.invoke(NativeMethodAccessorImpl.java:77) ~[?:?]
at jdk.internal.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethodAccessorImpl.java:43) ~[?:?]
at java.lang.reflect.Method.invoke(Method.java:568) ~[?:?]
at org.openhab.core.internal.common.AbstractInvocationHandler.invokeDirect(AbstractInvocationHandler.java:147) [bundleFile:?]
at org.openhab.core.internal.common.Invocation.call(Invocation.java:52) [bundleFile:?]
at java.util.concurrent.FutureTask.run(FutureTask.java:264) [?:?]
at java.util.concurrent.ThreadPoolExecutor.runWorker(ThreadPoolExecutor.java:1136) [?:?]
at java.util.concurrent.ThreadPoolExecutor$Worker.run(ThreadPoolExecutor.java:635) [?:?]
at java.lang.Thread.run(Thread.java:840) [?:?]
Possible Solution
I managed to fix on my side by deleting && stopCommandString != null in RollershutterValue.java:94 that comes from https://github.com/openhab/openhab-addons/pull/15875/
I guess it is only a workaround and the problem may be deeper
Steps to Reproduce (for Bugs)
- Create a Generic MQTT Thing
- Add a channel type Rollershutter (default configuration is good)
- Create an item of type Rollershutter linked to that channel
- Send command STOP to that item
Context
I saw the introduction of the bug was about mqtt.homeassistant. In my case, I only use mqtt.generic because I want to keep it simple and low level
Your Environment
- Version used: 4.1.1
- Environment name and version : openjdk 17.0.9, node 16.20.2
- Operating System and version : Openhabian (Raspbian 11)
About this issue
- Original URL
- State: closed
- Created 3 years ago
- Comments: 17 (7 by maintainers)
Commits related to this issue
- [mqtt.generic] default STOP to null for rollershutter channel Closes #16276 This is how it mostly works already anyway Signed-off-by: Cody Cutrer <cody@cutrer.us> — committed to ccutrer/openhab-addons by ccutrer 3 years ago
- [mqtt.generic] default STOP to null for rollershutter channel (#16345) Closes #16276 This is how it mostly works already anyway Signed-off-by: Cody Cutrer <cody@cutrer.us> — committed to openhab/openhab-addons by ccutrer 3 years ago
- [mqtt.generic] default STOP to null for rollershutter channel (#16345) Closes #16276 This is how it mostly works already anyway Signed-off-by: Cody Cutrer <cody@cutrer.us> Signed-off-by: Jørgen Aus... — committed to austvik/openhab-addons by ccutrer 3 years ago
- [mqtt.generic] default STOP to null for rollershutter channel (#16345) Closes #16276 This is how it mostly works already anyway Signed-off-by: Cody Cutrer <cody@cutrer.us> — committed to joni1993/openhab-addons by ccutrer 3 years ago
- [mqtt.generic] default STOP to null for rollershutter channel (#16345) Closes #16276 This is how it mostly works already anyway Signed-off-by: Cody Cutrer <cody@cutrer.us> Signed-off-by: Ciprian Pa... — committed to QDinsight/openhab-addons by ccutrer 3 years ago
Yes, definitely a weirdness with the default value. I was able to reproduce with a UI created generic MQTT thing, but not a file based (which is what the shades in my production instance are). I wrote a fix, but did not have time to test it yet. In the meantime, you can work around by explicitly setting
stop = "STOP"on the channel for a file based thing, or for a UI based thing, configure it to something else (like “ST”) first, save it, and then change it to “STOP” (do not click the little X to clear it and get the default) to get it to persist the literal string.