kubernetes: [Failing Test][sig-node] ci-cos-containerd-node-e2e and required presubmit CI pull-kubernetes-node-e2e-containerd
Which jobs are failing?
https://prow.k8s.io/view/gs/kubernetes-jenkins/logs/ci-cos-containerd-node-e2e/1753883638342094848
Which tests are failing?
- e2e.go: Node Tests expand_more 42m46s
- E2eNode Suite: [It] [sig-node] Pod SIGKILL [LinuxOnly] [NodeConformance] The containers terminated forcefully by Sigkill should have the correct exit code(137) and reason (Error) expand_more 10m3s
- E2eNode Suite: [It] [sig-node] Probing container should be restarted with an exec liveness probe with timeout [MinimumKubeletVersion:1.20] [NodeConformance] expand_more 4m2s
- E2eNode Suite: [It] [sig-network] Networking Granular Checks: Pods should function for intra-pod communication: http [NodeConformance] [Conformance] expand_more 14s
- E2eNode Suite: [It] [sig-network] Networking Granular Checks: Pods should function for node-pod communication: http [LinuxOnly] [NodeConformance] [Conformance] expand_more 1m16s
- E2eNode Suite: [It] [sig-node] Ephemeral Containers [NodeConformance] should update the ephemeral containers in an existing pod [Conformance] expand_more 4s
- E2eNode Suite: [It] [sig-node] Ephemeral Containers [NodeConformance] will start an ephemeral container in an existing pod [Conformance] expand_more 4s
- E2eNode Suite: [It] [sig-node] Container Lifecycle Hook when create a pod with lifecycle hook should execute poststart exec hook properly [NodeConformance] [Conformance] expand_more 5m2s
- E2eNode Suite: [It] [sig-node] [NodeConformance] Containers Lifecycle should call the container’s preStop hook and terminate it if its liveness probe fails expand_more 1m44s
- E2eNode Suite: [It] [sig-node] [NodeConformance] Containers Lifecycle should not launch second container before PostStart of the first container completed expand_more 4s
- E2eNode Suite: [It] [sig-node] PrivilegedPod [NodeConformance] should enable privileged commands [LinuxOnly] expand_more 2s
- E2eNode Suite: [It] [sig-node] Probing container should override timeoutGracePeriodSeconds when StartupProbe field is set [NodeConformance] expand_more 4m43s
- E2eNode Suite: [It] [sig-node] [NodeConformance] Containers Lifecycle should run Init container to completion before call to PostStart of regular container expand_more 6s
- E2eNode Suite: [It] [sig-node] Probing container should be restarted with a exec “cat /tmp/health” liveness probe [NodeConformance] [Conformance] expand_more 4m2s
- E2eNode Suite: [It] [sig-network] Networking Granular Checks: Pods should function for intra-pod communication: udp [NodeConformance] [Conformance] expand_more 16s
- E2eNode Suite: [It] [sig-node] Swap [NodeConformance] [LinuxOnly] with configuration QOS Guaranteed expand_more 2s
- E2eNode Suite: [It] [sig-node] Pods should support remote command execution over websockets [NodeConformance] [Conformance] expand_more 2s
- E2eNode Suite: [It] [sig-node] [NodeConformance] Containers Lifecycle should call the container’s preStop hook and terminate it if its startup probe fails expand_more 1m42s
- E2eNode Suite: [It] [sig-node] Container Lifecycle Hook when create a pod with lifecycle hook should execute prestop exec hook properly [NodeConformance] [Conformance] expand_more 36s
- E2eNode Suite: [It] [sig-node] Security Context [NodeConformance] [LinuxOnly] Container PID namespace sharing containers in pods using isolated PID namespaces should all receive PID 1 expand_more 2s
- E2eNode Suite: [It] [sig-node] Swap [NodeConformance] [LinuxOnly] with configuration QOS Burstable expand_more 2s
- E2eNode Suite: [It] [sig-node] Security Context [NodeConformance] [LinuxOnly] Container PID namespace sharing processes in containers sharing a pod namespace should be able to see each other expand_more 4s
- E2eNode Suite: [It] [sig-node] KubeletManagedEtcHosts should test kubelet managed /etc/hosts file [LinuxOnly] [NodeConformance] [Conformance] expand_more 4s
- E2eNode Suite: [It] [sig-node] Swap [NodeConformance] [LinuxOnly] with configuration QOS Best-effort expand_more 2s
- E2eNode Suite: [It] [sig-network] Networking Granular Checks: Pods should function for node-pod communication: udp [LinuxOnly] [NodeConformance] [Conformance] expand_more 1m16s
- E2eNode Suite: [It] [sig-node] Swap [NodeConformance] [LinuxOnly] with configuration QOS Burstable with memory request equals to limit expand_more
Since when has it been failing?
02-04 first failure https://prow.k8s.io/view/gs/kubernetes-jenkins/logs/ci-cos-containerd-node-e2e/1753883638342094848
Testgrid link
https://testgrid.k8s.io/sig-node-containerd#image-validation-node-e2e
Reason for failure (if possible)
{ failed [FAILED] Failed to await Pod (sigkill-test-6542/sigkill-pod-e1d4c8ed-fd7a-46fe-a56f-b3da64dc2e5e) become ready after registering signal handler: Timed out after 300.000s. The matcher passed to Eventually returned the following error: <*errors.errorString | 0xc000c003a0>: pod ‘sigkill-pod-e1d4c8ed-fd7a-46fe-a56f-b3da64dc2e5e’ on ‘tmp-node-e2e-01675d27-ubuntu-gke-2204-1-25-v20240203’ didn’t have condition {Ready True}; conditions: [{PodReadyToStartContainers True 0001-01-01 00:00:00 +0000 UTC 2024-02-03 21:05:54 +0000 UTC } {Initialized True 0001-01-01 00:00:00 +0000 UTC 2024-02-03 21:05:53 +0000 UTC } {Ready False 0001-01-01 00:00:00 +0000 UTC 2024-02-03 21:05:53 +0000 UTC ContainersNotReady containers with unready status: [sigkill-target-container]} {ContainersReady False 0001-01-01 00:00:00 +0000 UTC 2024-02-03 21:05:53 +0000 UTC ContainersNotReady containers with unready status: [sigkill-target-container]} {PodScheduled True 0001-01-01 00:00:00 +0000 UTC 2024-02-03 21:05:53 +0000 UTC }]
some potential reason log
https://storage.googleapis.com/kubernetes-jenkins/logs/ci-cos-containerd-node-e2e/1753883638342094848/artifacts/tmp-node-e2e-01675d27-ubuntu-gke-2204-1-25-v20240203/cloud-init.log and cloud-init.log and serial-1.log
in the failed CI job
Feb 03 21:02:24 ubuntu dhclient[354]: execve (/bin/true, ...): Permission denied
[ 0.000000] [Firmware Bug]: TSC doesn't count with P0 frequency!
[ 0.368418] smpboot: CPU0: AMD EPYC 7B12 (family: 0x17, model: 0x31, stepping: 0x0)
[ 0.368418] smpboot: CPU0: AMD EPYC 7B12 (family: 0x17, model: 0x31, stepping: 0x0)
[ 0.369959] Performance Events: AMD PMU driver.
[ 0.370642] ... version: 0
[ 0.371269] ... bit width: 48
[ 0.371309] ... generic registers: 4
[ 0.371311] ... value mask: 0000ffffffffffff
[ 0.372034] ... max period: 00007fffffffffff
[ 0.372832] ... fixed-purpose events: 0
[ 0.373385] ... event mask: 000000000000000f
[ 0.374192] signal: max sigframe size: 1776
[ 0.374858] rcu: Hierarchical SRCU implementation.
[ 0.375699] smp: Bringing up secondary CPUs ...
[ 0.376617] x86: Booting SMP configuration:
[ 0.377367] .... node #0, CPUs: #1
in the passed CI job
- [ 0.080936] Kernel/User page tables isolation: enabled
[ 0.512792] smpboot: CPU0: Intel(R) Xeon(R) CPU @ 2.20GHz (family: 0x6, model: 0x4f, stepping: 0x0)
[ 0.514936] Performance Events: unsupported p6 CPU model 79 no PMU driver, software events only.
[ 0.515582] signal: max sigframe size: 1776
[ 0.516667] rcu: Hierarchical SRCU implementation.
[ 0.518384] NMI watchdog: Perf NMI watchdog permanently disabled
[ 0.519619] smp: Bringing up secondary CPUs ...
[ 0.521096] x86: Booting SMP configuration:
[ 0.522258] .... node #0, CPUs: #1
Anything else we need to know?
No response
Relevant SIG(s)
/sig node
About this issue
- Original URL
- State: closed
- Created 3 years ago
- Comments: 20 (20 by maintainers)
we have one pass on the CI - https://prow.k8s.io/?job=ci-cos-containerd-node-e2e
good run, images used are - log: