mpp-solar: This entity is no longer being provided by the mqtt integration. If the entity is no longer in use, delete it in settings.
latest
mpp-solar -p /dev/hidraw2 -o screen -c QID#QDI#QMOD#QPI#QPIGS#QPIRI#QFLAG
Command: QID - Device Serial Number inquiry
--------------------------------------------------------------------------------
Parameter Value Unit
serial_number 55355535553555
Command: QDI - Default Settings inquiry
--------------------------------------------------------------------------------
Parameter Value Unit
ac_output_voltage 230.0 V
ac_output_frequency 50.0 Hz
max_ac_charging_current 30 A
battery_under_voltage 42.0 V
battery_float_charge_voltage 54.0 V
battery_bulk_charge_voltage 56.4 V
battery_recharge_voltage 46.0 V
max_charging_current 60 A
input_voltage_range Appliance
output_source_priority Utility first
charger_source_priority Solar + Utility
battery_type AGM
buzzer enabled
power_saving disabled
overload_restart disabled
over_temperature_restart disabled
lcd_backlight enabled
primary_source_interrupt_alarm enabled
record_fault_code enabled
overload_bypass disabled
lcd_reset_to_default enabled
output_mode single machine output
battery_redischarge_voltage 54.0 V
pv_ok_condition As long as one unit of inverters has connect PV, parallel system will consider PV OK
pv_power_balance PV input max power will be the sum of the max charged power and loads power
Command: QMOD - Mode inquiry
--------------------------------------------------------------------------------
Parameter Value Unit
device_mode Line
Command: QPI - Protocol ID inquiry
--------------------------------------------------------------------------------
Parameter Value Unit
protocol_id PI30
Command: QPIGS - General Status Parameters inquiry
--------------------------------------------------------------------------------
Parameter Value Unit
ac_input_voltage 214.3 V {'icon': 'lightning'}
ac_input_frequency 50.0 Hz
ac_output_voltage 214.3 V
ac_output_frequency 50.0 Hz
ac_output_apparent_power 0 VA
ac_output_active_power 0 W
ac_output_load 0 %
bus_voltage 362 V
battery_voltage 1.0 V
battery_charging_current 0 A
battery_capacity 0 %
inverter_heat_sink_temperature 28 °C
pv_input_current_for_battery 0.0 A
pv_input_voltage 0.0 V
battery_voltage_from_scc 0.0 V
battery_discharge_current 0 A
is_sbu_priority_version_added 0 bool
is_configuration_changed 0 bool
is_scc_firmware_updated 0 bool
is_load_on 1 bool
is_battery_voltage_to_steady_while_charging 0 bool
is_charging_on 0 bool
is_scc_charging_on 0 bool
is_ac_charging_on 0 bool
rsv1 0 A
rsv2 0 A
pv_input_power 0 W
is_charging_to_float 0 bool
is_switched_on 1 bool
is_reserved 0 bool
Command: QPIRI - Current Settings inquiry
--------------------------------------------------------------------------------
Parameter Value Unit
ac_input_voltage 230.0 V
ac_input_current 21.7 A
ac_output_voltage 230.0 V
ac_output_frequency 50.0 Hz
ac_output_current 21.7 A
ac_output_apparent_power 5000 VA
ac_output_active_power 5000 W
battery_voltage 48.0 V
battery_recharge_voltage 46.0 V
battery_under_voltage 42.0 V
battery_bulk_charge_voltage 56.4 V
battery_float_charge_voltage 54.0 V
battery_type AGM
max_ac_charging_current 2 A
max_charging_current 10 A
input_voltage_range UPS
output_source_priority Utility first
charger_source_priority Solar first
max_parallel_units 1 units
machine_type Off Grid
topology transformerless
output_mode single machine output
battery_redischarge_voltage 54.0 V
pv_ok_condition As long as one unit of inverters has connect PV, parallel system will consider PV OK
pv_power_balance PV input max power will be the sum of the max charged power and loads power
Command: QFLAG - Flag Status inquiry
--------------------------------------------------------------------------------
Parameter Value Unit
overload_bypass enabled
over_temperature_restart enabled
lcd_backlight enabled
primary_source_interrupt_alarm enabled
record_fault_code enabled
buzzer disabled
power_saving disabled
lcd_reset_to_default disabled
overload_restart disabled
Lot of entity’s are switched to Unavailable, previously working
QDI AC Output Frequency = 50.0 Hz
QDI AC Output Voltage = 230.0 V
QDI Battery Bulk Charge Voltage = 56.4 V
QDI Battery Float Charge Voltage = 54.0 V
QDI Battery Recharge Voltage = 46.0 V
QDI Battery Redischarge Voltage = 54.0 V
QDI Battery Type = AGM
QDI Battery Under Voltage = 42.0 V
QDI Buzzer = Unavailable
QDI Buzzer = On
QDI Charger Source Priority = Solar + Utility
QDI Input Voltage Range = Appliance
QDI LCD Backlight = Unavailable
QDI LCD Backlight = On
QDI LCD reset to default = Unavailable
QDI LCD reset to default = On
QDI Max AC Charging Current = 30 A
QDI Max Charging Current = 60 A
QDI Output mode = single machine output
QDI Output Source Priority = Utility first
QDI Over temperature restart = Unavailable
QDI Over temperature restart = Off
QDI Overload bypass = Unavailable
QDI Overload bypass = Off
QDI Overload restart = Unavailable
QDI Overload restart = Off
QDI Power saving = Unavailable
QDI Power saving = Off
QDI Primary source interrupt alarm = Unavailable
QDI Primary source interrupt alarm = On
QDI PV OK condition = As long as one unit of inverters has connect PV, parallel system will consider PV OK
QDI PV Power Balance = PV input max power will be the sum of the max charged power and loads power
QDI Record fault code = Unavailable
QDI Record fault code = On
QFLAG Buzzer = Unavailable
QFLAG Buzzer = Off
QFLAG LCD Backlight = Unavailable
QFLAG LCD Backlight = On
QFLAG LCD Reset to Default = Unavailable
QFLAG LCD Reset to Default = Off
QFLAG Over Temperature Restart = Unavailable
QFLAG Over Temperature Restart = On
QFLAG Overload Bypass = Unavailable
QFLAG Overload Bypass = On
QFLAG Overload Restart = Unavailable
QFLAG Overload Restart = Off
QFLAG Power Saving = Unavailable
QFLAG Power Saving = Off
QFLAG Primary Source Interrupt Alarm = Unavailable
QFLAG Primary Source Interrupt Alarm = On
QFLAG Record Fault Code = Unavailable
QFLAG Record Fault Code = On
QID Serial Number = 55355535553555
QMOD Device Mode = Line
QPI Protocol ID = PI30
QPIGS AC Input Frequency = 50.0 Hz
QPIGS AC Input Voltage = Unavailable
QPIGS AC Output Active Power = 0 W
QPIGS AC Output Apparent Power = 0 VA
QPIGS AC Output Frequency = 50.0 Hz
QPIGS AC Output Load = 0%
QPIGS AC Output Voltage = 209.4 V
QPIGS Battery Capacity = 0%
QPIGS Battery Charging Current = 0 A
QPIGS Battery Discharge Current = 0 A
QPIGS Battery Voltage = 0.9 V
QPIGS Battery Voltage from SCC = 0.0 V
QPIGS BUS Voltage = 360 V
QPIGS Inverter Heat Sink Temperature = 29 °C
QPIGS Is AC Charging On = Unavailable
QPIGS Is AC Charging On = Off
QPIGS Is Battery Voltage to Steady While Charging = Unavailable
QPIGS Is Battery Voltage to Steady While Charging = Off
QPIGS Is Charging On = Unavailable
QPIGS Is Charging On = Off
QPIGS Is Charging to Float = Unavailable
QPIGS Is Charging to Float = Off
QPIGS Is Configuration Changed = Unavailable
QPIGS Is Configuration Changed = Off
QPIGS Is Load On = Unavailable
QPIGS Is Load On = On
QPIGS Is Reserved = Unavailable
QPIGS Is Reserved = Off
QPIGS Is SBU Priority Version Added = Unavailable
QPIGS Is SBU Priority Version Added = Off
QPIGS Is SCC Charging On = Unavailable
QPIGS Is SCC Charging On = Off
QPIGS Is SCC Firmware Updated = Unavailable
QPIGS Is SCC Firmware Updated = Off
QPIGS Is Switched On = Unavailable
QPIGS Is Switched On = On
QPIGS PV Input Current for Battery = 0.0 A
QPIGS PV Input Power = 0 W
QPIGS PV Input Voltage = 0.0 V
QPIGS RSV1 = 0 A
QPIGS RSV2 = 0 A
QPIRI AC Input Current = 21.7 A
QPIRI AC Input Voltage = 230.0 V
QPIRI AC Output Active Power = 5,000 W
QPIRI AC Output Apparent Power = 5,000 VA
QPIRI AC Output Current = 21.7 A
QPIRI AC Output Frequency = 50.0 Hz
QPIRI AC Output Voltage = 230.0 V
QPIRI Battery Bulk Charge Voltage = 56.4 V
QPIRI Battery Float Charge Voltage = 54.0 V
QPIRI Battery Recharge Voltage = 46.0 V
QPIRI Battery Redischarge Voltage = 54.0 V
QPIRI Battery Type = AGM
QPIRI Battery Under Voltage = 42.0 V
QPIRI Battery Voltage = 48.0 V
QPIRI Charger Source Priority = Solar first
QPIRI Input Voltage Range = UPS
QPIRI Machine Type = Off Grid
QPIRI Max AC Charging Current = 2 A
QPIRI Max Charging Current = 10 A
QPIRI Max Parallel Units = 1 units
QPIRI Output Mode = single machine output
QPIRI Output Source Priority = Utility first
QPIRI PV OK Condition = As long as one unit of inverters has connect PV, parallel system will consider PV OK
QPIRI PV Power Balance = PV input max power will be the sum of the max charged power and loads power
QPIRI Topology = transformerless
No firmware or etc. changed.