solis-sensor: Wrong data in the morning energydashboard
Describe the bug Wrong data in the morning energydashboard
Config Solarman portal config m.ginlong.com (Solis inverter, Wifi dongle) not yet migrated
Versions HA Version 2022.x HACS version last 2 versions. Now 1.22.0 Integration version v2.0.6
Debug logs < Will do this when needed Add to configuration.yaml:
logger:
default: warning
logs:
custom_components.solis: debug
And attach the resulting log to the issue. If yo do not know where to find logs you missed an important step in the install of HACS. 😉
Screenshots

About this issue
- Original URL
- State: closed
- Created 2 years ago
- Comments: 21 (12 by maintainers)
You had some interrupts of service around that time:
I just release v2.0.7.
Looking at all the data you shared this should fix the issue. It also should address the issue of @LucidityCrash .
Let me know if it works.
Indeed, with normal battery-less inverters the daily energy is reset at inverter power-up in the morning. For you, with battery it is reset somewhere just after midnight. I think I can fix both scenarios. Pretty sure I have @mwitlox case fixed now (cannot reproduce myself, but should be okay). Going to give your scenario a try as well by ignoring any energy today data from the server the first 15 minutes of a day and just return ‘0’. Will run regression test tomorrow, if all passes will release later this week.