core: Modbus over TCP causes memory leak
The problem
Modbus integration causes memory leak. I have 14 energy meters connected via Modbus TCP (65 entities in total) and everyday I experience crash of HA production installation due to lack of memory and swap. The same occurs on clean Home Assistant Container installation from which I attach the logs. There’s nothing added in this clean installation except for System Monitor and Modbus integrations. I attach the screenshot of memory usage from both HA installations. Both installations use latest HA versions and the bug doesn’t relate to particular version.
What version of Home Assistant Core has the issue?
core-2024.9.3
What was the last working version of Home Assistant Core?
No response
What type of installation are you running?
Home Assistant Container
Integration causing the issue
Modbus
Link to integration documentation on our website
No response
Diagnostics information
home-assistant_modbus_2024-10-02T09-08-31.340Z.log
Example YAML snippet
modbus:
- name: "Miernik Energii Rozdzielnica"
type: tcp
host: "192.168.1.252"
port: 4196
sensors:
# Pompa CO Góra
- unique_id: pompa_co_gora_napiecie
name: Pompa CO Góra Napięcie
device_address: 1
address: 0
scan_interval: 2
input_type: input
data_type: float32
device_class: voltage
precision: 1
state_class: measurement
unit_of_measurement: V
- unique_id: pompa_co_gora_natezenie_pradu
name: Pompa CO Góra Natężenie prądu
device_address: 1
address: 8
scan_interval: 2
input_type: input
data_type: float32
device_class: current
precision: 2
state_class: measurement
unit_of_measurement: A
- unique_id: pompa_co_gora_moc
name: Pompa CO Góra Moc
device_address: 1
address: 18
scan_interval: 2
input_type: input
data_type: float32
device_class: power
precision: 1
state_class: measurement
unit_of_measurement: W
- unique_id: pompa_co_gora_power_factor
name: Pompa CO Góra Power factor
device_address: 1
address: 42
scan_interval: 2
input_type: input
data_type: float32
device_class: power_factor
precision: 2
state_class: measurement
- unique_id: pompa_co_gora_suma_dostarczonej_energii
name: Pompa CO Góra Suma dostarczonej energii
device_address: 1
address: 256
scan_interval: 2
input_type: input
data_type: float32
device_class: energy
precision: 2
state_class: total_increasing
unit_of_measurement: kWh
Anything in the logs that might be useful for us?
No response
Additional information
I’m using Waveshare 4-CH RS485 TO POE ETH (B) gateway to convert Modbus RTU to Modbus TCP.
About this issue
- Original URL
- State: closed
- Created 2 years ago
- Comments: 36 (10 by maintainers)
I think the simplest solution would be to use a DUC per entity which already has safe guards to prevent this problem.
While I could make the change, sadly I don’t have any modbus devices so test with it so it will need to wait for a developer who does
@joostlek I wasn’t able to run
py-spy top --pid 67due to errorError: Unsupported version of Python: 3.12.0.The callgrind files are attached attached but start_log_objects was interrupted by container crash due to lack of memory. I will try tomorrow. profile.zip
On 2025.1 I didn’t notice any improvement, memory still leaks as it was.
It seems nobody cares about one of major smart home communication protocols…
Unfortunately the yaml matches the spec and my suspect was wrong. The only further suggestion is to try break down the problem in smaller pieces, in example focusing on sensors coming from one device at a time and avoid to include sensors missing the answer as in example device 1.
I did it for all sensors, no worries 🙂 “It” stands for
scan_interval.