core: Modbus integration does not work since one of the last updates

The problem

I have two modbus connections:

  • one via a USB Dongle (connecting to a growatt inverter)
  • one via ethernet (connecting to a solvis heating system) Both stopped working at the same time. There are no sensor entities filled by modbus.

It worked fine for appr. 2 years and stopped working after one of the last updates. Sorry not to be precise - but I did several at once.

What version of Home Assistant Core has the issue?

2024.5.5

What was the last working version of Home Assistant Core?

2024.2

What type of installation are you running?

Home Assistant OS

Integration causing the issue

Modbus

Link to integration documentation on our website

https://www.home-assistant.io/integrations/modbus/

Diagnostics information

No response

Example YAML snippet

modbus:
  - name: modbus_growatt
    type: serial
    port: /dev/ttyACM0
    baudrate: 9600
    bytesize: 8
    method: rtu
    parity: E
    stopbits: 1

    delay: 2
    message_wait_milliseconds: 1000
    timeout: 5

    sensors:

      - name: growatt_modbus_SOC
        unit_of_measurement: '%'
        input_type: input
        address: 3171
        scan_interval: 120

      - name: growatt_modbus_discharge_power
        unit_of_measurement: 'W'
        input_type: input
        scale: 0.1
        address: 3178
        data_type: uint32
        scan_interval: 30

      - name: growatt_modbus_charge_power
        unit_of_measurement: 'W'
        input_type: input
        scale: 0.1
        address: 3180
        data_type: uint32
        scan_interval: 30

      - name: growatt_modbus_PV_total_power
        unit_of_measurement: 'W'
        input_type: input
        scale: 0.1
        address: 3001
        data_type: uint32
        scan_interval: 10

      - name: growatt_modbus_PaC_power #Output power
        unit_of_measurement: 'W'
        input_type: input
        scale: 0.1
        address: 3023
        data_type: uint32
        scan_interval: 30
        

      - name: growatt_modbus_P2user_power #Total forward power
        unit_of_measurement: 'W'
        input_type: input
        scale: 0.1
        address: 3041
        data_type: uint32
        scan_interval: 10

      - name: growatt_modbus_P2grid_power #Total reverse power
        unit_of_measurement: 'W'
        input_type: input
        scale: 0.1
        address: 3043
        data_type: uint32
        scan_interval: 10

      - name: growatt_modbus_P2load_power #Total load power - durrent consumption
        unit_of_measurement: 'W'
        input_type: input
        scale: 0.1
        address: 3045
        data_type: uint32
        scan_interval: 10

      - name: growatt_modbus_E2User_today_10fach #Today energy to user
        unit_of_measurement: 'kWh'
        input_type: input
        #scale: 0.1 #Scaling does not work with uint32 - but uint32 is needed for decoding
        address: 3067
        data_type: uint32
        scan_interval: 120    
        device_class: ENERGY 
        #state_class: total_increasing

      - name: growatt_modbus_E2Grid_today_10fach #Today energy to grid
        unit_of_measurement: 'kWh'
        input_type: input
        #scale: 0.1 #Scaling does not work with uint32 - but uint32 is needed for decoding
        address: 3071
        data_type: uint32
        scan_interval: 120    
        device_class: ENERGY 
        #state_class: total_increasing

      - name: growatt_modbus_EUserLoad_today_10fach #Today energy of user load
        unit_of_measurement: 'kWh'
        input_type: input
        #scale: 0.1 #Scaling does not work with uint32 - but uint32 is needed for decoding
        address: 3075
        data_type: uint32
        scan_interval: 120    
        device_class: ENERGY 
        #state_class: total_increasing

      - name: growatt_modbus_Discharge_today_10fach #Today discharge energy 0.1kWh
        unit_of_measurement: 'kWh'
        input_type: input
        #scale: 0.1 #Scaling does not work with uint32 - but uint32 is needed for decoding
        address: 3125
        data_type: uint32
        scan_interval: 120    
        device_class: ENERGY 
        state_class: total_increasing

      - name: growatt_modbus_Charge_today_10fach #Charge energy today
        unit_of_measurement: 'kWh'
        input_type: input
        #scale: 0.1 #Scaling does not work with uint32 - but uint32 is needed for decoding
        address: 3129
        data_type: uint32
        scan_interval: 120    
        device_class: ENERGY 
        state_class: total_increasing

      - name: growatt_modbus_PVEnergy_today_10fach #Charge energy today
        unit_of_measurement: 'kWh'
        input_type: input
        #scale: 0.1 #Scaling does not work with uint32 - but uint32 is needed for decoding
        address: 91
        data_type: uint32
        scan_interval: 120    
        device_class: ENERGY 
        state_class: total_increasing

      - name: growatt_modbus_SysEnergy_today_10fach #System energy today
        unit_of_measurement: 'kWh'
        input_type: input
        #scale: 0.1 #Scaling does not work with uint32 - but uint32 is needed for decoding
        address: 3123
        data_type: uint32
        scan_interval: 120    
        device_class: ENERGY 
        state_class: total_increasing

  - name: SolvisRemote
    type: tcp
    host: 192.168.178.120
    port: 502
    
    sensors:
    #  - name: Solvis_Warmwasserpuffer
    #    slave: 10
    #    address: 33024
    #    input_type: holding
    #    unit_of_measurement: °C
    #    count: 1
    #    scale: 0.1
    #    offset: 0
    #    precision: 2
    #    data_type: int32

      - name: Solvis_Speicher_oben
        unit_of_measurement: °C
        scale: 0.1
        slave: 1
        precision: 1
        input_type: holding
        address: 33024

      - name: Solvis_Warmwassertemperatur
        unit_of_measurement: °C
        scale: 0.1
        slave: 1
        precision: 2
        input_type: holding
        address: 33025

      - name: Solvis_Speicherreferenztemperatur
        unit_of_measurement: °C
        scale: 0.1
        slave: 1
        precision: 2
        input_type: holding
        address: 33026

      - name: Solvis_Heizungspuffertemperatur oben
        unit_of_measurement: °C
        scale: 0.1
        slave: 1
        precision: 2
        input_type: holding
        address: 33027

      - name: Solvis_Aussentemperatur
        unit_of_measurement: °C
        scale: 0.1
        slave: 1
        precision: 2
        input_type: holding
        address: 33033

      - name: Solvis_Heizungspuffertemperatur unten
        unit_of_measurement: °C
        scale: 0.1
        slave: 1
        precision: 2
        input_type: holding
        address: 33032

      - name: Solvis_Zirkulationsdurchfluss
        unit_of_measurement: °C
        scale: 0.1
        slave: 1
        precision: 2
        input_type: holding
        address: 33034

      - name: Solvis_Vorlauftemperatur
        unit_of_measurement: °C
        scale: 0.1
        slave: 1
        precision: 2
        input_type: holding
        address: 33035

      - name: Solvis_Kaltwassertemperatur
        unit_of_measurement: °C
        scale: 0.1
        slave: 1
        precision: 2
        input_type: holding
        address: 33038

      - name: Solvis_Durchfluss_Warmwasserzirkualation
        unit_of_measurement: l/min
        slave: 1
        precision: 2
        scale: 0.1
        input_type: holding
        address: 33041

      - name: Solvis_Laufzeit_Brenner
        unit_of_measurement: h
        slave: 1
        precision: 0
        input_type: holding
        address: 33536

      - name: Solvis_Brennerstarts
        unit_of_measurement: Starts 
        slave: 1
        precision: 0
        input_type: holding
        address: 33537

      - name: Solvis_Brennerleistung

        unit_of_measurement: kW
        scale: 0.1
        slave: 1
        precision: 2
        input_type: holding
        address: 33539

      - name: Solvis_Ionisationsstrom
        unit_of_measurement: mA 
        slave: 1
        scale: 0.1
        precision: 1
        input_type: holding
        address: 33540

      - name: Solvis_VersionSC2
        slave: 1
        scale: 0.01
        precision: 2
        input_type: holding
        address: 32770

      - name: Solvis_VersionNBG
        slave: 1
        scale: 0.01
        input_type: holding
        address: 32771

      - name: Solvis_ZirkulationBetriebsart
        slave: 1
        input_type: holding
        address: 2049

#      - name: Solvis_A01.Pumpe_Zirkulation
#        slave: 1
#        unit_of_measurement: V
#        scale: 0.01
#        precision: 0
#        input_type: holding
#        address: 33280

#      - name: Solvis_A02.Pumpe_Warmwasser
#        slave: 1
#        unit_of_measurement: V
#        scale: 0.01
#        precision: 0
#        input_type: holding
#        address: 33281

      - name: Solvis_A03.Pumpe_HK1
        slave: 1
        unit_of_measurement: V
        scale: 0.01
        precision: 0
        input_type: holding
        address: 33282

#      - name: Solvis_A12.Brennerstatus
#        slave: 1
#        unit_of_measurement: V
#        scale: 0.01
#        precision: 0
#        input_type: holding
#        address: 33291

      - name: Solvis_DigIn_Stoerungen
        slave: 1
        input_type: holding
        address: 33045

      - name: Solvis_HKR1_Betriebsart
        slave: 1
        input_type: holding
        address: 2818
        #        value_template: "{%if states.sensor.hkr1_betriebsart.state == '1' %}Aus{% elif states.sensor.hkr1_betriebsart.state == '2' %}Automatik{% elif states.sensor.hkr1_betriebsart.state == '3' %}Tagbetrieb{% elif states.sensor.hkr1_betriebsart.state == '4' %}Absenkbetrieb{% elif states.sensor.hkr1_betriebsart.state == '5' %}Standby{% elif states.sensor.hkr1_betriebsart.state == '6' %}Eco{% elif states.sensor.hkr1_betriebsart.state == '7' %}Urlaub{% elif states.sensor.hkr1_betriebsart.state == '8' %}WW Vorang{% elif states.sensor.zirkulationbetriebsart.state == '9' %}Frostschutz{% elif states.sensor.zirkulationbetriebsart.state == '10' %}Pumpenschutz{% elif states.sensor.hkr1_betriebsart.state == '11' %}Estrich{% endif %}"


      - name: Solvis_WW_Solltemperatur
        unit_of_measurement: °C
        slave: 1
        input_type: holding
        address: 2305

Anything in the logs that might be useful for us?

From the UI (Protocols)
Pymodbus: SolvisRemote: Error: device: 1 address: 33024 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
Pymodbus: modbus_growatt: Error: device: 0 address: 3178 -> Modbus Error: [Input/Output] ERROR: No response received after 3 retries

---
From the logfile:
2024-05-27 17:28:58.470 INFO (MainThread) [homeassistant.components.modbus] Modbus reloading
2024-05-27 17:28:58.472 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 33035 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:28:58.480 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 33038 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:28:58.481 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 33041 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:28:58.483 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 33536 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:28:58.484 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 33537 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:28:58.487 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 33539 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:28:58.488 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 33540 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:28:58.489 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 32770 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:28:58.490 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 32771 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:28:58.490 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 2049 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:28:58.491 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 33282 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:28:58.492 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 33045 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:28:58.493 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 2818 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:28:58.495 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 2305 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:28:59.489 DEBUG (MainThread) [pymodbus.logging] Connection lost comm due to Server not responding
2024-05-27 17:28:59.492 DEBUG (MainThread) [pymodbus.logging] callback_disconnected called: Server not responding
2024-05-27 17:28:59.493 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: modbus_growatt: Error: device: 0 address: 3043 -> Modbus Error: [Input/Output] ERROR: No response received after 3 retries
2024-05-27 17:28:59.494 DEBUG (MainThread) [pymodbus.logging] Wait comm 100.0 ms before reconnecting.
2024-05-27 17:28:59.596 DEBUG (MainThread) [pymodbus.logging] Connecting to /dev/ttyACM0.
2024-05-27 17:28:59.596 DEBUG (MainThread) [pymodbus.logging] Connecting comm
2024-05-27 17:28:59.604 DEBUG (MainThread) [pymodbus.logging] Connected to comm
2024-05-27 17:28:59.605 DEBUG (MainThread) [pymodbus.logging] Resetting frame - Current Frame in buffer - 
2024-05-27 17:29:00.496 DEBUG (MainThread) [pymodbus.logging] Adding transaction 472
2024-05-27 17:29:00.497 DEBUG (MainThread) [pymodbus.logging] Resetting frame - Current Frame in buffer - 
2024-05-27 17:29:00.497 DEBUG (MainThread) [pymodbus.logging] send: 0x0 0x4 0xb 0xe5 0x0 0x2 0x63 0xc9
2024-05-27 17:29:00.530 DEBUG (MainThread) [pymodbus.logging] recv: 0x1 0x4 0x4 0x0 0x0 0x64 0x3e 0x50 0x94 old_data:  addr=None
2024-05-27 17:29:00.530 DEBUG (MainThread) [pymodbus.logging] Processing: 0x1 0x4 0x4 0x0 0x0 0x64 0x3e 0x50 0x94
2024-05-27 17:29:00.531 DEBUG (MainThread) [pymodbus.logging] Getting Frame - 0x4 0x4 0x0 0x0 0x64 0x3e
2024-05-27 17:29:00.532 DEBUG (MainThread) [pymodbus.logging] Factory Response[ReadInputRegistersResponse': 4]
2024-05-27 17:29:00.532 DEBUG (MainThread) [pymodbus.logging] Frame advanced, resetting header!!
2024-05-27 17:29:00.533 DEBUG (MainThread) [pymodbus.logging] Getting transaction 1
2024-05-27 17:29:00.533 DEBUG (MainThread) [pymodbus.logging] Unrequested message: ReadInputRegistersResponse (2)
2024-05-27 17:29:05.500 DEBUG (MainThread) [pymodbus.logging] Adding transaction 472
2024-05-27 17:29:05.501 DEBUG (MainThread) [pymodbus.logging] Resetting frame - Current Frame in buffer - 
2024-05-27 17:29:05.501 DEBUG (MainThread) [pymodbus.logging] send: 0x0 0x4 0xb 0xe5 0x0 0x2 0x63 0xc9
2024-05-27 17:29:05.538 DEBUG (MainThread) [pymodbus.logging] recv: 0x1 0x4 0x4 0x0 0x0 0x65 0x36 0x50 0xc2 old_data:  addr=None
2024-05-27 17:29:05.539 DEBUG (MainThread) [pymodbus.logging] Processing: 0x1 0x4 0x4 0x0 0x0 0x65 0x36 0x50 0xc2
2024-05-27 17:29:05.539 DEBUG (MainThread) [pymodbus.logging] Getting Frame - 0x4 0x4 0x0 0x0 0x65 0x36
2024-05-27 17:29:05.540 DEBUG (MainThread) [pymodbus.logging] Factory Response[ReadInputRegistersResponse': 4]
2024-05-27 17:29:05.541 DEBUG (MainThread) [pymodbus.logging] Frame advanced, resetting header!!
2024-05-27 17:29:05.541 DEBUG (MainThread) [pymodbus.logging] Getting transaction 1
2024-05-27 17:29:05.541 DEBUG (MainThread) [pymodbus.logging] Unrequested message: ReadInputRegistersResponse (2)
2024-05-27 17:29:10.505 DEBUG (MainThread) [pymodbus.logging] Adding transaction 472
2024-05-27 17:29:10.505 DEBUG (MainThread) [pymodbus.logging] Resetting frame - Current Frame in buffer - 
2024-05-27 17:29:10.506 DEBUG (MainThread) [pymodbus.logging] send: 0x0 0x4 0xb 0xe5 0x0 0x2 0x63 0xc9
2024-05-27 17:29:10.542 DEBUG (MainThread) [pymodbus.logging] recv: 0x1 0x4 0x4 0x0 0x0 0x65 0x41 0x10 0xe4 old_data:  addr=None
2024-05-27 17:29:10.542 DEBUG (MainThread) [pymodbus.logging] Processing: 0x1 0x4 0x4 0x0 0x0 0x65 0x41 0x10 0xe4
2024-05-27 17:29:10.543 DEBUG (MainThread) [pymodbus.logging] Getting Frame - 0x4 0x4 0x0 0x0 0x65 0x41
2024-05-27 17:29:10.543 DEBUG (MainThread) [pymodbus.logging] Factory Response[ReadInputRegistersResponse': 4]
2024-05-27 17:29:10.543 DEBUG (MainThread) [pymodbus.logging] Frame advanced, resetting header!!
2024-05-27 17:29:10.544 DEBUG (MainThread) [pymodbus.logging] Getting transaction 1
2024-05-27 17:29:10.544 DEBUG (MainThread) [pymodbus.logging] Unrequested message: ReadInputRegistersResponse (2)
2024-05-27 17:29:13.303 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 33024 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:29:13.347 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 33025 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:29:13.349 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 33026 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:29:13.426 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 33027 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:29:13.428 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 33033 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:29:13.434 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 33032 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:29:13.436 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 33034 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:29:13.473 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 33035 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:29:13.480 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 33038 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:29:13.485 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 33041 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:29:13.490 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 33536 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:29:13.491 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 33537 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:29:13.492 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 33539 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:29:13.494 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 33540 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:29:13.495 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 32770 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:29:13.497 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 32771 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:29:13.498 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 2049 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:29:13.500 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 33282 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:29:13.501 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 33045 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:29:13.506 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 2818 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:29:13.507 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: SolvisRemote: Error: device: 1 address: 2305 -> Modbus Error: [Connection] Not connected[AsyncModbusTcpClient 192.168.178.120:502]
2024-05-27 17:29:15.510 DEBUG (MainThread) [pymodbus.logging] Adding transaction 472
2024-05-27 17:29:15.511 DEBUG (MainThread) [pymodbus.logging] Resetting frame - Current Frame in buffer - 
2024-05-27 17:29:15.511 DEBUG (MainThread) [pymodbus.logging] send: 0x0 0x4 0xb 0xe5 0x0 0x2 0x63 0xc9
2024-05-27 17:29:15.548 DEBUG (MainThread) [pymodbus.logging] recv: 0x1 0x4 0x4 0x0 0x0 0xd 0x27 0xbf 0xe old_data:  addr=None
2024-05-27 17:29:15.548 DEBUG (MainThread) [pymodbus.logging] Processing: 0x1 0x4 0x4 0x0 0x0 0xd 0x27 0xbf 0xe
2024-05-27 17:29:15.549 DEBUG (MainThread) [pymodbus.logging] Getting Frame - 0x4 0x4 0x0 0x0 0xd 0x27
2024-05-27 17:29:15.549 DEBUG (MainThread) [pymodbus.logging] Factory Response[ReadInputRegistersResponse': 4]
2024-05-27 17:29:15.550 DEBUG (MainThread) [pymodbus.logging] Frame advanced, resetting header!!
2024-05-27 17:29:15.550 DEBUG (MainThread) [pymodbus.logging] Getting transaction 1
2024-05-27 17:29:15.551 DEBUG (MainThread) [pymodbus.logging] Unrequested message: ReadInputRegistersResponse (2)
2024-05-27 17:29:20.515 DEBUG (MainThread) [pymodbus.logging] Connection lost comm due to Server not responding
2024-05-27 17:29:20.518 DEBUG (MainThread) [pymodbus.logging] callback_disconnected called: Server not responding
2024-05-27 17:29:20.519 DEBUG (MainThread) [homeassistant.components.modbus.modbus] Pymodbus: modbus_growatt: Error: device: 0 address: 3045 -> Modbus Error: [Input/Output] ERROR: No response received after 3 retries

Additional information

No response

About this issue

  • Original URL
  • State: closed
  • Created 2 years ago
  • Comments: 32 (17 by maintainers)

Most upvoted comments

Well if my somewhat longer explanation doesn’t help, then please do not forget I am a HA enthusiast like yourself, but also a volunteer and have more than enough to do, so believe me I am not sitting waiting for bug reports or enhancement requests.

Please do not expect me to solve your problem if you do not help identify the problem, to be blunt I solve bug reports fast, when the issuer identifies the problem, because that is the spirit of open source, but I have no obligation to do so !

I understand why you see it as your endpoint, but please also understand it is not my problem or in any way my obligation, I am just helping solve identified problems.

The only thing I see you do is deny the problem people have and not actually helping or putting them on the right track. I think this complete discussion is a waste of time!