core: Integration: wolflink , Missing some unit declarations for heat pumps regarding power and energy entities and some others

The problem

Some of the entities for a WOLF Link ISM7 with CHA 7 Heatpump are missing units. Thus their values are not showable as a history chart in entities details…

Because all power sensors dont have units, they are not convertet to german numbering (For example “Heat generator 1 Current secondary power” 2.6 should be 2,6 kW) German conversions do work for e.g. Temperatures.

What version of Home Assistant Core has the issue?

core-2025.2.3

What was the last working version of Home Assistant Core?

none (first usage of home assistant and Wolf SmartSet Service integration)

What type of installation are you running?

Home Assistant OS

Integration causing the issue

Wolf SmartSet Service, label:“integration: wolflink”

Link to integration documentation on our website

https://www.home-assistant.io/integrations/wolflink/

Diagnostics information

Copied from dashboard: HA_Wolf-SmartSet-Service_Integration_Entities_missing_units.csv

<html xmlns:v="urn:schemas-microsoft-com:vml" xmlns:o="urn:schemas-microsoft-com:office:office" xmlns:x="urn:schemas-microsoft-com:office:excel" xmlns="http://www.w3.org/TR/REC-html40"> <head> <meta name=ProgId content=Excel.Sheet> <meta name=Generator content="Microsoft Excel 14"> <link id=Main-File rel=Main-File href="file:///C:\Users\ditma\AppData\Local\Temp\msohtmlclip1\01\clip.htm"> <link rel=File-List href="file:///C:\Users\ditma\AppData\Local\Temp\msohtmlclip1\01\clip_filelist.xml"> <style> </style> </head> <body link=blue vlink=purple>
Entity name Value Missing Unit
Common settings Set value correction 0.5 => °C
Compressor frequency 25 => Hz
Heat generator 1 Current secondary power 2.6 => kW
Heat generator 1 HC flow rate 13.4 => l/min
Heat generator 1 Power consumption (WP + EHZ) 0.4 => kW
Statistics heat generator 1 Consumption current month 201 => kWh
Statistics heat generator 1 Consumption current year 588 => kWh
Statistics heat generator 1 Consumption previous day 15 => kWh
Statistics heat generator 1 Consumption previous year 582 => kWh
Statistics heat generator 1 Consumption year before last 0 => kWh
Statistics heat generator 1 Energy amount DHW 1852 => kWh
Statistics heat generator 1 Energy amount HTG 7487 => kWh
Statistics heat generator 1 Heat generated current month 674 => kWh
Statistics heat generator 1 Heat generated current year 2044 => kWh
Statistics heat generator 1 Heat generated previous day 48 => kWh
Statistics heat generator 1 Heat generated previous year 6701 => kWh
Statistics heat generator 1 Heat generated year before last 594 => kWh
</body> </html>

Example YAML snippet

non

Anything in the logs that might be useful for us?

non

Additional information

I asume that we are missing some unit definition in “sensor.py” for kW, Hz, rpm and l/min The Entity “Common settings Set value correction” is not marked for a Unit “°C”, so this temperature correction value is a SimpleParameter

About this issue

  • Original URL
  • State: closed
  • Created 2 years ago
  • Comments: 19 (5 by maintainers)

Most upvoted comments

Yeah they made me re-write the code for HA. So it’s going to be not in this release sadly. Instead of the 2 lines it’s many more hours now anyhow. The current under need lib doesn’t have support for that sensor yet. I’m just trying to implement what is there currently. I personally don’t heatpump so I will not be able to test it.

Just as an fyi I have a new library which will support the units which you guys are looking for, but it still needs testing and implementing as it also contains other bigger changes for this integration.

Tatsächlich. da macht man einmal nicht sofort das update und schon ist man zur stundenlanger Fehlersuche verdammt. Vielen Dank drose28357 für den entscheidenden Hinweis. Mit 2025.4-2 funktionierts.

Sorry da hätte ich auch wirklich selbst drauf kommen können.

@drose28357 I personally use all 3 together. You just need to make sure you don’t over pull the device specially from ism7mqtt. I can use my device over wolf, ism7mqtt and this integration.

I am experiencing the same problems, thanks for filing this issue.

Could you please doublecheck your suggestions for “Missing Unit”. I suppose all entities beginning with “Statistics heat generator 1” are energy units and thus the unit of measurement should be “kWh”.

“kW” is indeed correct for “Heat generator 1 Current secondary power” and “Heat generator 1 Power consumption (WP + EHZ)”