evcc: Go-e via OCPP charge meter: not available, meter energy: not available
Describe the bug
I have connected a Go-e Charger via OCPP to EVCC and see error logs that charge meter and meter energy are not available
Steps to reproduce
- connected a Go-e Charger via OCPP to EVCC
- restart the Go-e charger to trigger connect process
- observe the evcc logs …
Configuration details
---
network:
schema: "http"
host: "0.0.0.0"
port: 7070
interval: "2s"
sponsortoken: "..."
log: "debug"
levels:
ocpp: trace
meters:
- name: "eMallorca Lab"
type: "custom"
power:
source: "mqtt"
topic: "wa-pi/grid"
currents:
- source: "mqtt"
topic: "wa-pi/grid/p1"
- source: "mqtt"
topic: "wa-pi/grid/p2"
- source: "mqtt"
topic: "wa-pi/grid/p3"
chargers:
- name: "OCPP-1"
type: "template"
template: "ocpp"
host: "192.168.1.203"
idtag: 1
timeout: 3m
site:
title: "eMallorca"
meters:
grid: "eMallorca Lab"
pvs: []
batteries: []
loadpoints:
- title: "OCPP-1"
charger: "OCPP-1"
phases: 1
mode: "now"
mqtt:
broker: "192.168.1.132"
topic: "evcc"
user: "..."
password: "..."
Log details
Mar 11 10:43:51 iwattcontroller evcc[3395]: [ocpp ] DEBUG 2023/03/11 10:43:51 chargepoint connected: go-e-Charger-224285
Mar 11 10:43:51 iwattcontroller evcc[3395]: [ocpp ] TRACE 2023/03/11 10:43:51 received JSON message from go-e-Charger-224285: [2,"531531531","BootNotification",{"chargePointVendor":"go-e","chargePointModel":"go-eCharger_V4","chargePointSerialNumber":"224285","firmwareVersion":"055.0"}]
Mar 11 10:43:51 iwattcontroller evcc[3395]: [ocpp ] TRACE 2023/03/11 10:43:51 handling incoming CALL [531531531, BootNotification] from go-e-Charger-224285
Mar 11 10:43:51 iwattcontroller evcc[3395]: [ocpp ] TRACE 2023/03/11 10:43:51 sent CALL RESULT [531531531] for go-e-Charger-224285
Mar 11 10:43:51 iwattcontroller evcc[3395]: [ocpp ] TRACE 2023/03/11 10:43:51 sent JSON message to go-e-Charger-224285: [3,"531531531",{"currentTime":"2023-03-11T09:43:51Z","interval":60,"status":"Accepted"}]
Mar 11 10:43:51 iwattcontroller evcc[3395]: [ocpp ] TRACE 2023/03/11 10:43:51 received JSON message from go-e-Charger-224285: [2,"531531532","StatusNotification",{"connectorId":0,"errorCode":"NoError","status":"Available","timestamp":"2023-03-11T09:43:51.000Z"}]
Mar 11 10:43:51 iwattcontroller evcc[3395]: [ocpp ] TRACE 2023/03/11 10:43:51 handling incoming CALL [531531532, StatusNotification] from go-e-Charger-224285
Mar 11 10:43:51 iwattcontroller evcc[3395]: [ocpp ] TRACE 2023/03/11 10:43:51 sent CALL RESULT [531531532] for go-e-Charger-224285
Mar 11 10:43:51 iwattcontroller evcc[3395]: [ocpp ] TRACE 2023/03/11 10:43:51 sent JSON message to go-e-Charger-224285: [3,"531531532",{}]
Mar 11 10:43:51 iwattcontroller evcc[3395]: [ocpp ] TRACE 2023/03/11 10:43:51 received JSON message from go-e-Charger-224285: [2,"531531533","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":"Finishing","timestamp":"2023-03-11T09:43:51.000Z"}]
Mar 11 10:43:51 iwattcontroller evcc[3395]: [ocpp ] TRACE 2023/03/11 10:43:51 handling incoming CALL [531531533, StatusNotification] from go-e-Charger-224285
Mar 11 10:43:51 iwattcontroller evcc[3395]: [ocpp ] TRACE 2023/03/11 10:43:51 sent CALL RESULT [531531533] for go-e-Charger-224285
Mar 11 10:43:51 iwattcontroller evcc[3395]: [ocpp ] TRACE 2023/03/11 10:43:51 sent JSON message to go-e-Charger-224285: [3,"531531533",{}]
Mar 11 10:43:52 iwattcontroller evcc[3395]: [site ] DEBUG 2023/03/11 10:43:52 ----
Mar 11 10:43:52 iwattcontroller evcc[3395]: [lp-1 ] ERROR 2023/03/11 10:43:52 charge meter: not available
Mar 11 10:43:52 iwattcontroller evcc[3395]: [site ] DEBUG 2023/03/11 10:43:52 grid power: 537W
Mar 11 10:43:52 iwattcontroller evcc[3395]: [site ] DEBUG 2023/03/11 10:43:52 grid currents: [1.18 0.622 0.411]A
Mar 11 10:43:52 iwattcontroller evcc[3395]: [site ] DEBUG 2023/03/11 10:43:52 pv power: 0W
Mar 11 10:43:52 iwattcontroller evcc[3395]: [site ] DEBUG 2023/03/11 10:43:52 site power: 537W
Mar 11 10:43:52 iwattcontroller evcc[3395]: [lp-1 ] ERROR 2023/03/11 10:43:52 meter energy: not available
Mar 11 10:43:52 iwattcontroller evcc[3395]: [lp-1 ] DEBUG 2023/03/11 10:43:52 charger status: B
Mar 11 10:43:54 iwattcontroller evcc[3395]: [site ] DEBUG 2023/03/11 10:43:54 ----
What type of operating system are you running?
Linux
Version
evcc version 0.114.1
About this issue
- Original URL
- State: closed
- Created a year ago
- Comments: 17 (10 by maintainers)
The described problem is solved on Go-e Charger side, tested positively after Go-e firmware upgrade, see attached log evcc go-e on:off 2023-04-05.log
V.a., siehe auch https://github.com/evcc-io/evcc/discussions/3806#discussioncomment-5292105, erstmal ohne das ganze Voodoo probieren. Insbesondere
meter
gibts schon lange nicht und das tut gar nichts.Was hier in die Suppe spucken könnte ist das
In dem Fall senden wir die Phasenumschaltung mit was laut https://github.com/evcc-io/evcc/discussions/3806#discussioncomment-5253836 problematisch sein kann. Das könnten wir bei Bedarf aber auch unterdrücken- 1p3p geht dann aber nicht.
Jetzt warten wir aber erstmal ab was @thomas-hutterer-tik an Logfile produziert.
@knese danke, Fehler gefunden. Go-E schickt Messwerte, das ist aber read-only. Anderes Problem, Fix folgt: https://github.com/evcc-io/evcc/issues/6807