evcc: Go-e via OCPP charge meter: not available, meter energy: not available

Describe the bug

I have connected a Go-e Charger via OCPP to EVCC and see error logs that charge meter and meter energy are not available

Steps to reproduce

  1. connected a Go-e Charger via OCPP to EVCC
  2. restart the Go-e charger to trigger connect process
  3. observe the evcc logs …

Configuration details

---
network:
  schema: "http"
  host: "0.0.0.0"
  port: 7070
interval: "2s"
sponsortoken: "..."
log: "debug"
levels:
  ocpp: trace
meters:
- name: "eMallorca Lab"
  type: "custom"
  power:
    source: "mqtt"
    topic: "wa-pi/grid"
  currents:
  - source: "mqtt"
    topic: "wa-pi/grid/p1"
  - source: "mqtt"
    topic: "wa-pi/grid/p2"
  - source: "mqtt"
    topic: "wa-pi/grid/p3"
chargers:
- name: "OCPP-1"
  type: "template"
  template: "ocpp"
  host: "192.168.1.203"
  idtag: 1
  timeout: 3m
site:
  title: "eMallorca"
  meters:
    grid: "eMallorca Lab"
    pvs: []
    batteries: []
loadpoints:
- title: "OCPP-1"
  charger: "OCPP-1"
  phases: 1
  mode: "now"
mqtt:
  broker: "192.168.1.132"
  topic: "evcc"
  user: "..."
  password: "..."

Log details

Mar 11 10:43:51 iwattcontroller evcc[3395]: [ocpp  ] DEBUG 2023/03/11 10:43:51 chargepoint connected: go-e-Charger-224285
Mar 11 10:43:51 iwattcontroller evcc[3395]: [ocpp  ] TRACE 2023/03/11 10:43:51 received JSON message from go-e-Charger-224285: [2,"531531531","BootNotification",{"chargePointVendor":"go-e","chargePointModel":"go-eCharger_V4","chargePointSerialNumber":"224285","firmwareVersion":"055.0"}]
Mar 11 10:43:51 iwattcontroller evcc[3395]: [ocpp  ] TRACE 2023/03/11 10:43:51 handling incoming CALL [531531531, BootNotification] from go-e-Charger-224285
Mar 11 10:43:51 iwattcontroller evcc[3395]: [ocpp  ] TRACE 2023/03/11 10:43:51 sent CALL RESULT [531531531] for go-e-Charger-224285
Mar 11 10:43:51 iwattcontroller evcc[3395]: [ocpp  ] TRACE 2023/03/11 10:43:51 sent JSON message to go-e-Charger-224285: [3,"531531531",{"currentTime":"2023-03-11T09:43:51Z","interval":60,"status":"Accepted"}]
Mar 11 10:43:51 iwattcontroller evcc[3395]: [ocpp  ] TRACE 2023/03/11 10:43:51 received JSON message from go-e-Charger-224285: [2,"531531532","StatusNotification",{"connectorId":0,"errorCode":"NoError","status":"Available","timestamp":"2023-03-11T09:43:51.000Z"}]
Mar 11 10:43:51 iwattcontroller evcc[3395]: [ocpp  ] TRACE 2023/03/11 10:43:51 handling incoming CALL [531531532, StatusNotification] from go-e-Charger-224285
Mar 11 10:43:51 iwattcontroller evcc[3395]: [ocpp  ] TRACE 2023/03/11 10:43:51 sent CALL RESULT [531531532] for go-e-Charger-224285
Mar 11 10:43:51 iwattcontroller evcc[3395]: [ocpp  ] TRACE 2023/03/11 10:43:51 sent JSON message to go-e-Charger-224285: [3,"531531532",{}]
Mar 11 10:43:51 iwattcontroller evcc[3395]: [ocpp  ] TRACE 2023/03/11 10:43:51 received JSON message from go-e-Charger-224285: [2,"531531533","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":"Finishing","timestamp":"2023-03-11T09:43:51.000Z"}]
Mar 11 10:43:51 iwattcontroller evcc[3395]: [ocpp  ] TRACE 2023/03/11 10:43:51 handling incoming CALL [531531533, StatusNotification] from go-e-Charger-224285
Mar 11 10:43:51 iwattcontroller evcc[3395]: [ocpp  ] TRACE 2023/03/11 10:43:51 sent CALL RESULT [531531533] for go-e-Charger-224285
Mar 11 10:43:51 iwattcontroller evcc[3395]: [ocpp  ] TRACE 2023/03/11 10:43:51 sent JSON message to go-e-Charger-224285: [3,"531531533",{}]
Mar 11 10:43:52 iwattcontroller evcc[3395]: [site  ] DEBUG 2023/03/11 10:43:52 ----
Mar 11 10:43:52 iwattcontroller evcc[3395]: [lp-1  ] ERROR 2023/03/11 10:43:52 charge meter: not available
Mar 11 10:43:52 iwattcontroller evcc[3395]: [site  ] DEBUG 2023/03/11 10:43:52 grid power: 537W
Mar 11 10:43:52 iwattcontroller evcc[3395]: [site  ] DEBUG 2023/03/11 10:43:52 grid currents: [1.18 0.622 0.411]A
Mar 11 10:43:52 iwattcontroller evcc[3395]: [site  ] DEBUG 2023/03/11 10:43:52 pv power: 0W
Mar 11 10:43:52 iwattcontroller evcc[3395]: [site  ] DEBUG 2023/03/11 10:43:52 site power: 537W
Mar 11 10:43:52 iwattcontroller evcc[3395]: [lp-1  ] ERROR 2023/03/11 10:43:52 meter energy: not available
Mar 11 10:43:52 iwattcontroller evcc[3395]: [lp-1  ] DEBUG 2023/03/11 10:43:52 charger status: B
Mar 11 10:43:54 iwattcontroller evcc[3395]: [site  ] DEBUG 2023/03/11 10:43:54 ----

What type of operating system are you running?

Linux

Version

evcc version 0.114.1

About this issue

  • Original URL
  • State: closed
  • Created a year ago
  • Comments: 17 (10 by maintainers)

Most upvoted comments

The described problem is solved on Go-e Charger side, tested positively after Go-e firmware upgrade, see attached log evcc go-e on:off 2023-04-05.log

V.a., siehe auch https://github.com/evcc-io/evcc/discussions/3806#discussioncomment-5292105, erstmal ohne das ganze Voodoo probieren. Insbesondere meter gibts schon lange nicht und das tut gar nichts.

Was hier in die Suppe spucken könnte ist das

ConnectorSwitch3to1PhaseSupported (r/o): true

In dem Fall senden wir die Phasenumschaltung mit was laut https://github.com/evcc-io/evcc/discussions/3806#discussioncomment-5253836 problematisch sein kann. Das könnten wir bei Bedarf aber auch unterdrücken- 1p3p geht dann aber nicht.

Jetzt warten wir aber erstmal ab was @thomas-hutterer-tik an Logfile produziert.

@knese danke, Fehler gefunden. Go-E schickt Messwerte, das ist aber read-only. Anderes Problem, Fix folgt: https://github.com/evcc-io/evcc/issues/6807