CoolProp: Wrong values for temperature-dependent sigma of water in PC-SAFT

The parameters used for the sigma of water here is not the default one from Cameretti and Sadowski (they seem to have been obtained from a paper by Baird et al.):

https://github.com/CoolProp/CoolProp/blob/ffa5a278ab5fbf19282b66cb7a183861578dfc11/src/Backends/PCSAFT/PCSAFTFluid.cpp#L58-L66

The actual values should be:

params.sigma = 2.7927 + 10.1100*exp(-0.01775*t)-1.41700*exp(-0.01146*t)

About this issue

  • Original URL
  • State: open
  • Created 3 years ago
  • Comments: 22 (11 by maintainers)

Most upvoted comments

Here is a working example:

using Clapeyron

model = ePCSAFT(["water"], ["sodium", "chloride"])
V = 1/55757.07260200306
T = 298.15
z = [0.90, 0.05, 0.05]
p = pressure(model, V, T, z) # 2.372571785875148e8